NetworX Version 3 Installation Manual
103
Segment 3
1 = On: enables opening and closing reports
2 = On: enables zone bypass reporting
3 = On: enables zone restore reporting
4 = On: enables zone trouble reporting
5 = On: enables zone tamper reporting
6 = On: enables the cancel reporting
7 = On: enables the recent closing report
8 = On: enables the exit error report
Segment 4
1 = On: enables late to close / early to open reporting
2 = On: enables auto arm in STAY mode
3 = On: enables instant NIGHT mode
4 = On: tamper when sensor lost if armed
5 = On: enables instant STAY mode (toggle)
6 = On: arming allowed with tamper memory / communication failure/ expander
trouble
7 = On: arming allowed with battery trouble
8 = On: keyswitch zone arms in STAY mode
Segment 5
1 = On: Disables auto-bypassing of force armable zones at the end of the exit
delay
2 = Reserved
3 = Reserved
4 = Reserved
5 = Reserved
6 = Reserved
7 = Reserved
8 = Reserved
Entry/Exit timers
LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data)
Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times.
Segment 1
Entry time 1 This is the entry time that will be used when a delay 1 zone
type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 2
Exit time 1 This is the exit time that will be used for all zones designated
as delay 1.
Valid entries are 10-255 seconds.
Segment 3
Entry time 2 This is the entry time that will be used when a delay 2 zone
type initiates an entry delay.
Valid entries are 10-255 seconds.
Segment 4
Exit time 2 This is the exit time that will be used for all zones designated
as delay 2.
Valid entries are 10-255 seconds.