EasyManua.ls Logo

GE NetworX V3 - Setting Installer Messages; Setting the Keypad Partition and Keypad Number; Setting the Exit Buzzer Options

GE NetworX V3
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NetworX Version 3 Installation Manual
162
3. Scroll to Language 2 and press OK.
4. Use the ½¾ keys to select Français and press OK.
5. The keypad returns to Set KP Language.
6. Repeat these steps to set other languages.
Setting installer messages
Up to four messages can be displayed on the LCD when the keypad is idle or when it times out from
a menu. If you enable more than one message, the messages are shown in a continuous cycle.
Installer custom message
Date and time
Service required message
System ready/not ready
To enable the custom message:
1. Navigate with the ½¾ keys to This Keypad and press OK.
2. Select Keypad Features>Custom Message and press OK. The current status of the
installer message is displayed. In this case, it is disabled by default.
3. Use the ½¾ keys to change the status to enabled and press OK.
4. The keypad beeps once to accept the change and returns to Custom Message.
To edit the custom message:
1. Navigate with the ½¾ keys to This Keypad and press OK.
2. Select Program KP Text, press OK, and then select a language using the ½¾ keys.
3. Scroll to Zones/Messages>Custom Message, press OK, and then edit the appropriate line
of the message.
4. Press OK. The keypad beeps once to accept the change and returns to Custom Message.
Edit the other line of the message, if required.
Setting the keypad partition and keypad number
When you first power up the keypad, you are prompted to set the language, the default country and
the partition and keypad number for the current keypad. The keypad can connect to the bus only after
you set these numbers. The partition number and keypad number prompts are displayed for the initial
setting only. To change these numbers again, scroll to This Keypad>Partition Number and This
Keypad>Keypad Number.
Setting the exit buzzer options
You can configure a behaviour of the warning signal emitted during the exit delay, when the user is
leaving premises. The menu entries responsible for the keypad buzzer are partially located in the

Table of Contents