NetworX Version 3 Installation Manual
275
Manual Dialer Test
This menu option is added to the User Menu in the EN 50131 Mode. It allows the user to
manually test the dialer when the Dialer Fault is signalled by the system.
Mandatory Event Log
This menu option is added to the User Menu in the EN 50131 Mode. It allows the user to
review the mandatory log.
Holdup alarm
Switching to the EN 50131 Mode changes the “24h Silent” zone type into the “Holdup” zone type.
Two new events: “Holdup” and “Holdup Restore” are also added to the system.
The holdup zone can be activated by a switch, a push button, or a panic button on a keyfob assigned
to the holdup zone type. Activated holdup zones generate a holdup event. Holdup is a silent alarm
with reported HA SIA code. Holdup state is also indicated with the Trouble icon (a triangle with an
exclamation mark) on the keypad. Holdup restore event (HR SIA code) is sent only after the holdup
alarm is acknowledged by the user with the Fault Acknowledging/Overriding functionality.
Note: It’s recommended to change names of holdup zones to adequate names reflecting their functionality.
Fire alarm
The Fire alarm function is an additional function for the EN 50131 compliance.
Keyfobs
Using keyfobs in EN 50131-compliant systems is prohibited.
Scheduled arming/disarming
Scheduled arming/disarming in EN 50131-compliant systems is prohibited.
RF Receivers
Attenuated mode
According to the EN 50131, 6dB attenuation of RF link is required during installation to ensure that
during normal system operation environmental changes wouldn’t influence system stability. To enter
the attenuated mode, select RF Recevers>Receiver Features>Attenuated mode>Enable. Attenuation
command is executed only in the programming mode and can be disabled manually by the installer
with the Attenuated mode menu option or is disabled automatically when switching from the
programming mode to the user mode.