NetworX Version 3 Installation Manual
57
4. The keypad beeps once to confirm the change and returns to 24-hour.
5. Scroll to Attributes>Swinger Zone>Yes and press OK.
6. The keypad beeps once to confirm the change and returns to Swinger Zone.
7. Set the value of Inputs>Swinger Count to 5. For more information see Setting swinger
count below.
Setting swinger count
The swinger shutdown function allows the selected zone to be automatically bypassed after a
specified number of alarms. To configure swinger count, you must enable the advanced menu. The
following example sets swinger count to 5. This means that any zone for which swinger shutdown is
enabled can be activated five times within one arm period before it is automatically bypassed.
Bypassing a swinger zone also resets the counter for that zone to zero.
1. Ensure the advanced menu is enabled.
2. Navigate with the ½¾ keys to Control Panel>Inputs>Swinger Count and press OK.
3. Enter 5 and press OK.
4. The keypad beeps once to confirm the change and returns to Swinger Count.