EasyManuals Logo
Home>GE>Security System>NetworX V3

GE NetworX V3 User Manual

GE NetworX V3
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #95 background imageLoading...
Page #95 background image
NetworX Version 3 Installation Manual
95
LOCATION 2 - COMMUNICATOR FORMAT FOR PHONE N° 1 (1 segment, numerical data)
Location 2 contains the communicator format used to transmit to the receiver that is connected to
phone N°1. Consult the instructions for your central station receiver to determine which format is
compatible. See Appendix 3 for all available format selections. If you require a format other than
those listed, review the override options described in location 18 in order to create the appropriate
format. In order to create a special format, a “15” must be programmed in location 2 in addition to
the entries in location 18. If this location contains a “0”, the built-in communicator will be disabled,
and the NetworX V3 will function as a ‘local only’ control.
LOCATION 3 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 1 (2 segm., numerical data)
Segment 1- Dial attempts: Location 3, segment 1 is used to enter the number of dial attempts (1 to
15) which the communicator will make to phone N°1 before it ends the notification process. Factory
default is “8” and the communicator will make 8 attempts to the first number.
Note: There will be a waiting time of 12 seconds between the first two dial attempts, and a waiting time of 60 seconds
between each subsequent dial attempt.
Segment 2 - Phone N° 1 backup control: Programming a “0” in segment 2 of this location will
cause the NetworX V3 to make the designated number of attempts to phone N°2 before setting the
“Fail To Communicate” condition and stop reporting. Programming a “1” in this segment will cause
the NetworX V3 to stop trying to communicate after the designated number of attempts have been
made to phone N°1. If a “2” is programmed in this segment, it will cause the NetworX V3 to make
the dial attempts in increments of two. The first two attempts will be made to phone N°1, the next
two attempts to phone N°2, then repeating until the total number of attempts designated in Segment 1
is completed.
Reporting events to phone number 1
Phone N°1 has two programming locations that are used to select the events which are reported to
this phone number.
Location 4 is used to select which events are reported to phone N°1. Location 5 is used to select
which partitions are reported to phone N°1. If you do not want dual or split reporting, use location 4
to select all events to phone N°1, and leave location 5 at the factory default of “0”. If you want dual
or split reporting, and the split is based on the event type (such as alarm, open/close, etc.), you should
use location 4 to select only those events that should be reported to phone N°1, and you should leave
location 5 at the factory default of “0”. If you want dual or split reporting, and the split is based on
partition, you should program location 4 as a “0” and use location 5 to select those partitions that are
to be reported to phone N°1. If no events are to be reported to phone N°1, both locations should be
programmed as “0”.
LOCATION 4 - EVENTS REPORTED TO PHONE N° 1 (2 segments, feature selection data)
Segment 1
1 = Alarms
2 = Opening and closings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX V3 and is the answer not in the manual?

GE NetworX V3 Specifications

General IconGeneral
BrandGE
ModelNetworX V3
CategorySecurity System
LanguageEnglish

Related product manuals