NetworX Version 3 Installation Manual
209
Reporting protocols and formats
Reporting fixed codes in SIA and Contact ID
Table 28 lists the event codes sent for different reports (if enabled) when using SIA and Contact ID
formats. The numbers in brackets following the event is the number that is reported as the zone
number. If there are no parentheses, the zone is 0. An asterisk represents the first character from the
event code of the zone that is bypassed or in trouble.
Table 28. Event codes
Report Contact ID SIA Report Contact ID
SIA
Manual test 601 RX Keypad tamper 137 TA
Autotest 602 RP Keypad panic (audible) 120 PA
Open (user number) 401 OP Keypad panic (silent) 121 HA
Close (user number) 401 CL Duress 121 HA
Cancel (user number) 406 OC Keypad auxiliary 1 110 FA
Download complete 412 RS Keypad auxiliary 2 100 MA
Start program 627 LB RF sensor lost (zone number) 381 *T
End program 628 LX
RF sensor restore (zone
number)
381 *R
Recent close (user number) 401 CR
Sensor low battery (zone
number)
384 XT
Exit error (user number) 457 EE
Sensor battery restore (zone
number)
384 XR
Event log full 605 JL Zone trouble (zone number) 380 *T
Fail to communicate 354 RT
Zone trouble restore (zone
number)
380 *R
Expander trouble (device
number)
333 ET Zone tamper (zone number) 137 TA
Expander restore (device
number)
333 ER
Zone tamper restore (zone
number)
137 TR
Telephone fault 351 LT Zone bypass (zone number) 570 *B
Telephone restore 351 LR Bypass restore (zone number) 570 *U
Siren tamper (device
number)
321 YA Early open/late close 451 OK
Siren restore (device
number)
321 YH Zone activity fault 391 NA
Aux power over current
(device number)
312 YP Zone activity restore 391 NS
Aux power restore (device
number)
312 YQ Fail to close 454 CI