NetworX Version 3 Installation Manual
108
LOCATION 34 - PARTITION SELECT, ZONES 33-40 (8 segments of feature selection data)
Location 34 is used to select the partition(s) in which zones 33-40 reside. A zone may reside in any
combination of the 4 partitions. If a burglary zone resides in more than 1 partition, that zone will only
be active when all partitions are armed. A zone that resides in more than 1 partition will be reported
to its lowest partition. Segment 1 corresponds to zone 33 and segment 8 corresponds to zone 40.
Segment 1-8
1 = Partition 1
2 = Partition 2
3 = Partition 3
4 = Partition 4
LOCATION 35 - ZONES 41-48 CONFIGURATION GROUP (8 segments of numerical data)
Location 35 contains the configuration group (zone type) for zones 41-48. Segment 1 is for zone 41,
and segment 8 is for zone 48. You will find the default configurations in the table above.
LOCATION 36 - PARTITION SELECT, ZONES 41-48 (8 segments, feature selection data)
Location 36 is used to select the partition or partitions in which zones 41-48 reside. A zone may
reside in any combination of the 4 partitions. If a burglary zone resides in more than 1 partition, that
zone will only be active when all the partitions are armed. A zone that resides in more than 1
partition will be reported to its lowest partition. Location 36 has 8 segments. Segment 1 corresponds
to zone 41 and segment 8 corresponds to zone 48.
Segment 1-8
1 = Partition 1
2 = Partition 2
3 = Partition 3
4 = Partition 4
General options
LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data)
Location 37 is used to enable various system feature and reporting options. Please note that since the
I/O module in the wireless siren acts as an output expander, the wireless siren's behaviour is different
than the BELL output's behaviour in some cases.
Segment 1
1 = On: if siren sounds for “Telephone Line Cut” when armed
2 = On: if siren sounds for “Telephone Line Cut” when disarmed
3 = On: if siren* blast at arming (pulse)
4 = On: if siren* blast at exit expiration (pulse)
5 = On: if siren* blast at closing kiss-off (pulse)
6 = On: if siren sounds during a “Cross Zone” verification time
7 = On: if siren sounds for a zone or box tamper
8 = On: if siren* blasts 1 time for keyswitch or wireless arming; 2 times for
disarming
* BELL output only on NetworX V3