LOCATION 29 - ZONES 17-24 CONFIGURATION GROUP (8 segments, numerical data)
Location 29 contains the configuration group (zone type) for zones 17-24. Segment 1 is for zone 17,
segment 8 is for zone 24. You will find the default configurations in the table above.
LOCATION 30 - PARTITION SELECT, ZONES 17-24 (8 segments, feature selection data)
Location 30 is used to select the partition(s) in which zones 17-24 reside. A zone may reside in any
combination of the 4 partitions. If a burglary zone resides in more than 1 partition, that zone will only
be active when all the partitions are armed. A zone that resides in more than 1 partition will be
reported to its lowest partition. Location 30 has 8 segments. Segment 1 corresponds to zone 17 and
segment 8 corresponds to zone 24.
Segment 1-8
1 = Partition 1
2 = Partition 2
3 = Partition 3
4 = Partition 4
LOCATION 31 - ZONES 25-32 CONFIGURATION GROUP (8 segments, numerical data)
Location 31 contains the configuration group (zone type) for zones 25-32. Segment 1 is for zone 25,
segment 8 is for zone 32. You will find the default configurations in the table above.
LOCATION 32 - PARTITION SELECT, ZONES 25-32 (8 segments, feature selection data)
Location 32 is used to select the partition(s) in which zones 25-32 reside. A zone may reside in any
combination of the 4 partitions. If a burglary zone resides in more than 1 partition, that zone will only
be active when all the partitions are armed. A zone that resides in more than 1 partition will be
reported to its lowest partition. Segment 1 corresponds to zone 25 and segment 8 corresponds to zone
32.
Segment 1-8
1 = Partition 1
2 = Partition 2
3 = Partition 3
4 = Partition 4
LOCATION 33 - ZONES 33-40 CONFIGURATION GROUP (8 segments, numerical data)
Location 33 contains the configuration group (zone type) for zones 33-40. Segment 1 is for zone 33,
and segment 8 is for zone 40. You will find the default configurations in the table above.