NetworX Version 3 Installation Manual
210
Report Contact ID SIA Report Contact ID
SIA
Low battery (device
number)
309 YT RF jamming 344 XQ
Low battery restore (device
number)
309 YR RF jamming restore 344 XH
Mains fail (device number) 301 AT Smoke detector clean me 393 YX
Mains restore (device
number)
301 AR
Smoke detector clean me
restore
393 YZ
Box tamper (device
number)
137 TA
Box tamper restore (device
number)
137 TR
Special Reports
Table 29. Special Reports
Report Contact ID SIA
Fail to communicate over PSTN 354 (0) RT000
GSM module problem 354 (1) RT001
Fail to communicate over SMS 354 (2) RT002
Fail to communicate over GPRS 354 (2) RT002
GSM Login Failure 351 (193) LT193
GSM Login Success 351 (193) LR193
Low RSSI 351 (194) LT194
Good RSSI 351 (194) LR194
GPRS Down 351 (195) LT195
GPRS OK 351 (195) LR195
RSSI Value combined with test call (vvv= RSSI
value)
RXvvv
SMS SIA reporting message format
SIA reporting over SMS can be set to one of three modes: separate events, combined events and
reporting with partition modifiers.
Separate events
Account codes are used to identify partitions. Events for separate account codes are sent in separate
messages using the syntax:
>aaaaaa eennn [eennn …].
See
Table 30 for a detailed syntax description.