LOCATION 13 - ACCOUNT CODE FOR PHONE N° 3 (6 segments, numerical data)
Use location 13 to program the account code that is sent when phone N°3 is dialled. A zero in the
account code is programmed as a “0”. A “10” indicates the end of the account code, so program a
“10” in the segment immediately after the last digit of the account code. If the account code is 6
digits long, program all 6 segments. If location 6 is left un-programmed, account code 1 will be used
when phone N°3 is dialled.
LOCATION 14 - COMMUNICATOR FORMAT FOR PHONE N° 3 (1 segment, numerical data)
Location 14 contains the communicator format used to transmit to the receiver that is connected to
phone N°3. Consult the instruction manual for your central station receiver in order to determine
which format is compatible. See Appendix 3 for all available format selections. If you require a
format other than those listed, review the override options described in location 18 to create the
appropriate format. In order to create a special format, a “15” must be programmed in location 14, in
addition to the entries in location 18. If this location contains a “0”, format 1 will be used when
phone N°3 is dialled.
LOCATION 15 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE N° 3 (2 segments, numerical
data)
Segment 1, dial attempts: Segment 1 of location 15 is used to enter the number of dial attempts (1
to 15) that the communicator will make to phone N°3 before it ends the notification process. Factory
default is “0”, and the communicator will make the same number of attempts as those programmed in
location 3.
There will be a waiting time of 12 seconds between the first two dial attempts, and a waiting time of
60 seconds between each subsequent dial attempt (regardless of the number dialled).
Segment 2 - Phone N° 3 backup control: Programming a “0” in segment 2 of this location will
cause the NetworX V3 to make the designated number of attempts to phone N°2 before setting the
“Fail To Communicate” condition and stop reporting. Programming a “1” in this segment will cause
the NetworX V3 to stop trying to communicate after the designated number of attempts have been
made to phone N°3. If a “2” is programmed in this segment, it will cause the NetworX V3 to make
the dial attempts in increments of two. The first two attempts will be made to phone N°3, the next
two attempts to phone N°2, then repeating until the total number of attempts designated in segment 1
is completed.
Reporting events to phone number 3
Phone N°3 can be used as a third receiver to multi-report or split report events. Phone N°3 has two
programming locations that are used to select the events that are reported to this phone number.
Location 16 is used to select which events are reported to phone N°3, and location 17 is used to select
which partitions are reported to phone N°3. If you do not want dual or split reporting, location 16 and
location 17 should be left at the factory default of “0”. If you want multi-reporting or split reporting,
and the split is based on the event type (such as alarm, open/close, etc.), then location 16 should be
used to select only those events that should be reported to phone N°3, and location 17 should be left