NetworX Version 3 Installation Manual
72
Location Term Definition
2.1.3.1.1.7 Entry Guard A zone type that reduces false alarms. If an armed entry
guard zone is opened, the keypad sounder activates and
the entry delay starts before creating an alarm. This can be
programmed as a zone type.
2.1.3.1.1.8 Cross Zone A zone type that requires two or more trips within a
specified time before it will report an alarm.
2.1.3.1.1.9 Trouble A zone type that sends an alarm when the system is armed
and trouble when the system is disarmed.
2.1.3.1.1.10 Follower/Access
A zone type that follows a state of the entry/exit zone.
Usually it is a delayed zone when the system is open, and
an instant burglary zone during non-entry times This option
allows to toggle the follower setting. This option is visible
only if the 24-hour input type option is disabled.
2.1.3.1.2 Zone Type Name A menu option that specifies the name of a particular zone
type. This option also allows the name to be edited.
2.1.3.1.3 Attributes A menu entry that groups the additional characteristics of
the selected zone type.
2.1.3.1.3.1 End of Line Resistor A zone characteristic that specifies that two 3k3 end of line
resistors are used.
An end of line resistor (EOL) is a resistor that is placed on
the line to stop the signal being bounced back.
2.1.3.1.3.2 Defeat EOL Resistor A menu option that disables the end of line resistor of the
specified zone type.
2.1.3.1.3.3 Loop Response A zone characteristic of on-board control panel zones that
specifies the response rate. This can be either 500 ms or 50
ms.
2.1.3.1.3.4 Swinger Zone A zone characteristic that allows the selected zone to be
automatically bypassed after a specified number of
alarms.
2.1.3.1.3.5 Bypassable A zone characteristic that allows the zone to be bypassed.
2.1.3.1.3.6 Force Armable A zone characteristic that allows the zone to be force
armed.
2.1.3.1.3.7 Group Bypass A zone characteristic that allows the user to bypass
multiple zones with a single operation.
2.1.3.1.3.8 Zone Activity Monitor A zone characteristic that sends a report to the central
station when the zone does not change conditions within a
specified time period.
2.1.3.1.3.9 Access Control A zone characteristic that enables the zone to act as an
access entry point (door shunt). Do not enable this setting
unless the system is configured with a door control.
2.1.3.1.3.10 Pulsed Keyswitch A zone characteristic that allows a zone input to be used
with a momentary keyswitch. Each activation of the
keyswitch toggles the armed state of the control. This