NetworX Version 3 Installation Manual
87
Location Term Definition
2.5.1.1.3 Entry Time 2 A menu option that sets the time within which the user
must disarm the partition before a full alarm occurs. This
time can be between 10 and 255 seconds.
2.5.1.1.4 Exit Time 2 A menu option that sets the time within which the user
must leave the protected zone after arming the partition
before a full alarm occurs. When arming in Away mode, the
keypad can beep to warn the user (see keypad menu
options), also System Arming, Leave Now screen displays
until the end of the exit delay time. This time can be
between 10 and 255 seconds.
2.5.1.2 Feature Select A menu entry that groups all optional features relating to
partitions.
2.5.1.2.1 Arming A menu entry that groups the arming characteristics of the
selected partition.
2.5.1.2.1.1 Quick Arm A menu option that enables the function keys for part
arming and for full arming. These options work on a single-
partition keypad only. If the Quick Arm menu option is
enabled, the user can arm the system by simply pressing
the Arm Away, Arm Stay or Night Mode button, otherwise it
is necessary to enter the user code first. (To arm a system
in the Away mode with a single-partition keypad it is
enough to enter the user code).
2.5.1.2.1.2 Re-exit A menu option that enables the exit delay without
disarming the partition.
The exit delay can be restarted if in arm stay mode by
using the Arm Away command in the user menu or by
pressing a function key programmed by the installer to
activate arm away.
2.5.1.2.1.3 Silent Auto Arm A menu option that arms the partition automatically at a
preset time without the keypad buzzer sounding.
2.5.1.2.1.4 Automatic Instant A menu option that enables the automatic instant feature
of entry zones.
If no exit is detected (the entry/exit zone is not opened and
closed) after the partition is armed, the entry delay timer is
cancelled, creating an instant zone. If the exit is detected
(the user leaves the premises after arming the partition),
the entry timer stays active, creating an entry delay.
2.5.1.2.1.5 Final Set Door A menu option applicable for secondary entry/exit zones
only (zones with Delay 2 option set).
If the final set door option is enabled, the exit time will
immediately expire as soon as the secondary entry/exit
zone becomes ready again (the door is opened and closed
when the user leaves the premises). This feature can only
be used in combination with magnetic door contacts.
2.5.1.2.1.6 Instant Night A menu option that enables the instant Night mode
selection from the keypad (no toggle). In this mode, the
control panel will bypass all zones that have the Entry
Guard feature enabled, and the partition will be armed
without an exit delay. The partition must be disarmed to
cancel this mode.