APS-7000 Series User Manual
132
13. Press the Range key repeatedly to set the
voltage range for the Vset parameter. The
Range will be shown in the top corner.
LO(155V), MD(310V), HI(600V,
optional), Auto
14. Go to the Vset setting and set the output
voltage for the step. If the input setting voltage
doesn’t appear in the selected voltage range,
an “Over Range” alarm will appear during
Sequence. At this time, the output voltage
maintains on the previous setting voltage
value.
0 ~ 310V (range dependent)
(600V optional)
CT (Constant), KP (Keep), SP
(Sweep)
Note: Step 0 can only be set to CT
or SP.
When output has been executed under Standard
Mode, press the [Test] key to enter Sequence Mode,
and then execute step 0 to set output value.
15. Go to the Fset setting and set the frequency of
the step.
45.00 ~ 500.0Hz(1000Hz optional)