SRPU LEDs
Figure 59 LEDs on an LSQ1SRP2XB0
1 2 3 4
5
6
2
1: CF card status LED 2: XFP interface status LEDs
3: Management Ethernet interface status LEDs 4: Power and fan status LEDs
5: Card status LEDs 6: SRPU active/standby status LED
Management Ethernet interface status LEDs
The SRPU provides two management Ethernet interface status LEDs—LINK and ACT—to indicate the link
status and data forwarding status of the management Ethernet interface.
Table 54 Management Ethernet interface status LED description
LEDs
LINK ACT
Description
On Blinking
A link is present, and the management Ethernet interface is transmitting
data.
On Off A link is present.
Off Off No link is present.
Power status LEDs (PWR)
• If an SRPU provides only one power status LED (PWR), see Table 55 for the LED description.
• If an SRPU provides multiple LEDs with numbers (for example, PWR1 and PWR2), each LED
corresponds to a pluggable power module with the same number (the power module number is
marked on the chassis). See Table 56 for the LED description.
Table 55 Description of PWR LEDs without numbers
LEDs
OK FAIL
Description
On Off All power modules in the chassis are working properly.
Off On
A power module has no power output. (The cause can be: the power
module is faulty or not switched on; a power cable connection problem
occurs; the external power supply is unavailable.)
Off Off
This status occurs in the following cases:
• No power module is installed in the chassis.
• No power modules in the chassis output power. (The cause can be:
the power modules are faulty or not switched on; a power cable
connection problem occurs; the external power supply is unavailable.)