Displaying the operating status of fans
Use the display fan command to display the operating status of fans:
<Sysname> display fan
Fan 1 State: Normal
Table 24 Output description
Field Remarks
Fan 1 Fan number
State
Fan status:
Normal—The fan is correctly operating.
Absent—The fan is absent.
Fault—The fan has failed.
Displaying the operating status of power modules
Use the display power command to display the operating status of power modules:
<Sysname> display power
Power 1 State: Normal
Power 2 State: Absent
Table 25 Output description
Field Description
Power 1 Power module number
State
Power module status:
Normal—The power module is correctly operating.
Absent—The power module is absent.
Fault—The power module has failed.
Configuring load sharing for SRPUs
If your S7500E switch has two SRPUs, you can enable the load sharing function to load balance inter-LPU
traffic between the SRPUs. By default, the load sharing function is disabled, and only the active SRPU
forwards inter-LPU traffic.
Follow these steps to enable the load sharing function for SRPUs:
To do… Use the command… Remarks
Enter system view system view
Enable the load sharing function
for SRPUs
loadsharing enable
Optional
Disabled by default.
NOTE:
Load sharing is applicable only to unicast traffic.
The S7502E switches are designed to work in load sharing mode, and do not support the command.