6 - Maintenance
151
Fit the filter in the correct direction of air flow taking into account
the marking of the direction indication affixed to it.
Place the frame equipped with the filter in the housing
Screw completely the 4 screws (1).
Air conditioning compressor
The belt of compressor drive should be checked regularly.
Loosen the counter nut (1).
Screw the nut (2) to retain the belt, then tighten the counter nut
(1).
Air Conditioning gas
Checking the R134a charge load. It should be carried by a specialist. The filter driers is replaced every 5 years.