5 - Operation
126
2. Simultaneously press the Chemical Container Cleaning lever and the TurboFiller suction valve. This rinses the chemical
container with the flushing nozzle, while the rinsing liquid is emptied out of the TurboFiller.
TurboFiller rinsing - TurboFiller lid is closed
1. Close TurboFiller lid.
2. Turn the suction SmartValve towards “Rinsing tank” or “External Filling Device”, if clean water is available here.
3. Open the Turbo Deflector Valve for 1 minute to get plenty of clean water through the hoses.
4. Simultaneously press the Chemical Container Cleaning lever and the TurboFiller suction valve. This rinses the hopper
with the flushing nozzle, while the rinsing liquid is emptied out of the TurboFiller.
5. Rinse the hopper for 30-40 seconds.
6. Open the lid to inspect if the TurboFiller is empty. If not, close the lid again and press the TurboFiller suction valve, until
the TurboFiller is empty.
7. After the last flushing, the TurboFiller suction valve must be open for at least 20 seconds, after the rinse water is no
longer visible in the hopper, in order to completely empty the transfer hoses into the main tank.
μ
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying. This is to ensure that it is clean,
before spraying other crops that may be sensitive to the chemicals just used. See the section “Cleaning” on page 130
for details.
BoomPrime
The BoomPrime system works automatically, and it is activated, when a spray job is prepared:
1. Unfold the boom and turn on the PTO.
2. Set pressure valve to “Spraying”, suction valve to “Main tank” and
agitation valve to “Agitation”, if needed.
3. Adjust the spray pressure to what will be used when spraying.
4. The boom will then be fully primed within 1-2 minutes.
If the nozzles start to leak, when closing one or more sections during a
spray job, proceed as follows:
1. Adjust the pressure on the BoomPrime pressure regulation.
2. Turn pressure valve to “Main tank”.
3. Disconnect the PTO.
If adjustment of the BoomPrime system might be necessary, please refer to “BoomPrime Adjustment” on page 75.
BoomFlush - Manual Cleaning
When having the BoomFlush valves fitted to the end(s) of boom piping, the cleaning procedure is as follows:
1. Follow the cleaning procedure to clean the sprayer the first two times.
2. Open all BoomFlush valves by hand.
3. Continue the cleaning procedure to clean the sprayer for the third time.
4. Close BoomFlush valves.
±
WARNING! To prevent contamination of the soil, the BoomFlush valves must only be opened at the last step of
cleaning!