Page 4-16 (Rev. 4.1/ SW v1.60/ December 2006)
Available FEC rates are:
1/4
1/3
2/5
1/2
3/5
2/3
3/4
4/5
5/6
7/8
8/9
9/10
SPECTRAL INVERSION
The Spectral Inversion menu is used for setting the spectral inversion mode.
Spectral Inversion
1 AUTOMATIC
2{ INVERTED
3{ NORMAL
The available options are:
AUTOMATIC – the PVR 6000 automatically detects and sets the Spectral
Inversion Mode
INVERTED – sets the PVR 6000 receiver to “inverted” Spectral Inversion
Mode.
NORMAL - sets the PVR 6000 receiver to normal Spectral Inversion Mode.
LNB POWER SUPPLY
The LNB Power Supply menu is used for setting the power supply voltage level
to the LNB in order to control the received signal polarization.
LNB Power Supply
1 13V (VERTICAL)
2{ 18V (HORIZONTAL)
3{ OFF
The available options are:
13V (VERTICAL) – sets the LNB polarization to vertical
18V (HORIZONTAL) - sets the LNB polarization to horizontal
OFF –power to the LNB is disabled.