Note
Up to 4 rules can be set.
10.
Se
t arming schedule. See
Set Arming Schedule .
11.
Se
t linkage method. See
Linkage Method Sengs .
8.2.2 Set Line Crossing Detecon
Line crossing detecon is used to detect the object movement of crossing a predened line. When
it occur
s, the device takes linkage acons as response.
Before You Start
Go to VCA → Select Applicaon to select Smart Event, and click Next to enable the funcon.
Steps
1.
Go to VCA → Set Applicaon → Smart Event → Line Crossing Detecon .
2.
Select a channel.
3.
Check Enable.
4.
Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related acon
during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
5.
Adjust the live image to the desired scene by using PTZ control buons.
6.
Dr
aw detecon line.
1) Select a Line No.. Up to 4 lines can be set in the scene.
2) Click
.
A y
ellow line is displayed on live image.
3) Click on the line, and drag its end points to adjust the length and posion.
4) Select the
Direcon for the detecon line.
Direcon
It stands for the direcon from which the object goes across the line.
A<->B
The object g
oing across the line from both direcons can be detected and alarms are
triggered.
A->B
Only the object crossing the congured line from side A to side B can be detected.
B->A
Only the object cr
ossing the congured line from side B to side A can be detected.