8.2.3 Set Region Entrance Detecon
Region entrance detecon is used to detect the object movement of entering a predened area.
When it occurs, the device takes linkage acons as response.
Be
fore You Start
Go to VCA → Select Applicaon to select Smart E
vent, and click Next to enable the funcon.
Steps
1.
Go to VCA → Set Applicaon → Smart Event → Region Entrance Detecon .
2.
Select a channel.
3.
Check Enable.
4.
Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related acon
during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
5.
Adjust the live image to the desired scene by using PTZ control buons.
6.
Oponal: Set the minimum size and the maximum size for the target to improve detecon
accuracy. Only targets whose size are between the maximum size and the minimum size trigger
the detecon.
1) Click Max. Size, and drag the mouse on live image. If you want to change the size, click the
buon and draw again.
2)
Click Min. Size, and drag the mouse on the live image. If you want to change the size, click the
buon and draw again.
7.
Set detecon parameters.
Sensivity It stands for the sensivity of detecng an target. The higher the value is,
the mor
e easily the target is detected.
Detecon
Target
You can specify the object type, and the device only detects the selected
type of objects.