F 3335 (0622)
245
1 List of suitable (Ex)i solenoid valves
This list is not intended to be complete. All data listed are without guarantee. The manufactur-
ers’ data sheets are authoritative.
1.1 Safety-related (Ex)i solenoid valves
(up to SIL 4 according to IEC 61508)
1)
Hold values
1.2 (Ex)i solenoid valves
Manufacturer Type
Minimum pick-up values
U
an
I
an
Eugen Seitz
(Pilot valves)
11 G 52
121.11.01
121.11.02
121.11.03
121.113.23
PV 12F73 Ci oH
133.288.00
PV 12F73 Xi oH
127.991.00
PV 12F73 Xi oH-2
128.319.00
13 V
15 V
14 V
14 V
14 V
6.4 V
7 V
16 mA
12 mA
16 mA
16 mA
2.2 mA
1.5 mA
4.4 mA
Norgren Herion
(directly controlled
valves)
2001, 2002 22 V
5 V
1)
40 mA
1)
Manufacturer Type
Minimum pick-up values
U
an
I
an
ASCO Joucomatic
(directly controlled
valves)
IMXX
(ISSC, WPIS) 21.6 V
11 V
1)
28 mA
1)
Bürkert
(Pilot valves)
0590
5470
6516/6517
6518/6519
8640
6106
10.4 V
10.8 V
29 mA
30 mA
Norgren Herion
(Pilot valves)
2032
2033
2034
2035
2036
2037
2038
8.2 V
9.0 V
10.0 V
11.5 V
13.0 V
14.4 V
15.9 V
34 mA
30 mA
27 mA
25 mA
23 mA
21 mA
19 mA