1. APPROVALS AND STANDARDS
Designed to comply with:
EN 60079-29-1 General Requirements and performance.
EN 50271 Software and Digital Technologies.
Meets Exe isolation requirements for 50V operation.
DEKRAEXAMGmbH,EC-typeexaminationcerticateBVS04ATEX
G 001 X
Note: If compliance with the EC-type examination certicate BVS 04
ATEX G 001 X is required, refer to chapter 10 ‘Special Conditions
for Safe Use’. Ensure that all conditions therein are met.
2. ENVIRONMENTAL
Operating Temperature: -5
O
C to +55
O
C.
(*0
O
C for EXAM approved systems)
Storage Temperature: -25
O
C to +55
O
C.
Humidity: 0 to 90% RH. Non-condensing.
3. RFI/EMC CONFORMITY
EMC Directive 2004/108/EC
Conforms to:
EN50270: 2006 EMC/RFI
LV Directive 73/23/EEC
Constructed in accordance with good engineering practice. Guided by
the principles of EN 61010/1 1990/1992.