94 PC45 Series Printer User Guide
Maintenance Alerts
To view these settings:
From the printer Main Menu, select Settings > System Settings > Maintenance
Alerts.
From the printer web page, click Configure > System Settings > Maintenance
Alerts.
Alerts
System alerts include error and warning.
Maintenance
Alerts Setting
Description Default
Odometer (User
Resettable)
Sets the length of media (in meters) that the printer prints
before the Odometer (User Resettable) alert is sent, if this
alert is configured. Unit of measurement is defined in the Unit
of Measure parameter. Range is 0 to 4294967295.
0
Odometer (Printer) Sets the length of media (in meters) that the printer prints
before the Odometer (Printer) alert is sent. Unit of
measurement is defined in the Unit of Measure parameter.
Range is 0 to 4294967295.
0
Odometer (Printhead) Sets the length of media (in meters) that the printer prints
before the Odometer (Current Printhead) alert is sent, if this
alert is configured. Unit of measurement is defined in the Unit
of Measure parameter. Range is 0 to 4294967295.
0
Replace Printhead Sets the length of media (in meters) that the printer prints
before the Replace Printhead alert is sent, if this alert is
configured. Unit of measurement is defined in the Unit of
Measure parameter. Range is 0 to 4294967295.
0
Clean Printhead Sets the length of media (in meters) that the printer prints
before the Clean Printhead alert is sent, if this alert is
configured. Unit of measurement is defined in the Unit of
Measure parameter. Range is 0 to 4294967295.
0
Faulty Dot Sets the number of faulty dots on the printhead before the
Faulty Dot alert is sent, if this alert is configured. Range is
0 to 4294967295.
0
Ribbon Low Diameter Sets the minimum diameter of the ribbon roll before the
Ribbon Low alert is sent, if this alert is configured. Range is 0
to 200 mm.
0
Alert Description
Status Determines if an alert is sent out for a specific error.
Delay Repeats Sets how often the alert is sent out for a specific printer event. Range is 1 to
65535.
Delay Unit Selects the unit of measure that determines how often the alert is sent out.
Message Sets the message that is sent out with alert for a specific printer event.