Chapter 5 – General Operation
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
105
General Considerations - For most propellers, the values
used in the horsepower entry field are close to those that can
balance in one or two runs. Some installations may require
different sensitivity because of the aircraft configuration (for
example, pusher propellers require less weight than would be
indicated by their horsepower).
NOTE: The Set Sensitivity feature only applies to the
propeller balance channels the user selected in the
Propeller Balance Setup screens.
Use the following values to set sensitivity:
Weight in grams per IPS
Phase correction in clock hours
If these sensitivities are known from having balanced a similar
installation in the past, the user may enter them manually for a
high probability of achieving a balance in two engine runs. The
sections that follow explain these concepts.
? SENSITIVITY
SETUP
► [ 35.00]
GMS/IPS
► [12:00] CLOCK ANGLE
CORRECTION
► RESTORE/RESET
FIELD
if ok, push
START
SELECT TO ENTER
CORRECT WEIGHT
SELECT TO ENTER
CORRECT PHASE