Chapter 5 – General Operation
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
117
5.4.3 Obtaining Balance Solutions
After the balance reading displays and the user presses the
START key, the Vibrex unit presents its recommended weight
change solution (in grams) at a specific clock angle.
The illustration below shows an example of a typical Vibrex
unit’s Solution screen.
5.4.3.1
Application Guidelines
In applying balance solutions, use the following guidelines:
There may be some cases where the user cannot physically
place the weight at a specified location, or the user must add
balance weights different from those specified. To account
for these variations, the user must input the weight and clock
angle of the actual adjustment into the Vibrex unit.
If the specified weight differs from that added to the
propeller or the angle placement is different than that
► VIEW PROP MEASURMENT
RUN 1 ADJUSTMENT
► ADD [ 5.2 ] GMS
► AT [ 1:29] (split)
? FOLLOW INSTRUCTIONS
next run, push START
SELECT TO VIEW
MEASUREMENT
AGAIN
SELECT TO
ENTER ACTUAL
ANGLE USED
SELECT TO ENTER
ACTUAL WEIGHT
ADDED (IN GRAMS)
SELECT FOR PROPELLER