Chapter 5 General Operation
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
113
4. If one or more readings become suspect for any reason, the
user may retake a reading by pressing the REDO MEAS
context key. This action automatically erases the former
reading.
CAUTION: Pressing GO BACK cancels
(undoes or erases) the measurement.
5. If the current reading is correct, press START to advance to
the next screen.
NOTE: High-horsepower, coarse pitch propellers may stall
at a maximum static RPM. Do not attempt a balance with
the propeller stalling, because the resulting balance
reading in this situation is inaccurate. A propeller is
stalling if there is a noticeable change in the propeller’s
sound, from what the user normally hears.
RUN 1 PROP MEAS
08APR00 09:31:08 #1A
[ANNOTATE]
480 RPM
0.15 IPS @ 7:29
ID: -1
REDO MEAS
solution push START
DATE, TIME, AND
CHANNEL NUMBER.
USE TO ENTER
NOTES TO ONE’S
SELF
RPM (AZIMUTH),
IPS (VIBRATION),
AND PHASE
MEASUREMENTS
SELECT TO START
THE RUN OVER AND
RETAKE A
MEASUREMENT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Vibrex 2000 and is the answer not in the manual?

Honeywell Vibrex 2000 Specifications

General IconGeneral
BrandHoneywell
ModelVibrex 2000
CategoryTest Equipment
LanguageEnglish

Related product manuals