Chapter 5 General Operation
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
175
Choosing this option will open a set of menus that allow you
to exclude and/or edit individual adjustment points. If any
adjustment points are excluded in the lower menus, the key
will change to ADJ PTS: [INCL ALL] indicating that only
selected adjustment points are used in the solution. This list
can be seen by pressing the ADJ PTS key. If there are no
excluded points then the EXCLUDE key will be set to
<NONE> and the Excluded Adj Points list will be empty.
Pressing EDIT ADJ POINTS will transition to a screen that
allows you to select the change type. In most cases there will
only be one change type available but for “non-orthogonal”
solutions (solutions that unequal correction angles or
sensitivities, i.e. many tail rotors) there may be two, e.g.
Span Weight and Chord Weight. Select change type and then
? SELECT ADJ POINTS
EXCLUDE: <NONE>
Excluded Adj Points:
EDIT ADJ POINTS
if ok, push START
? EDIT ADJ PT SETTING
PREV
Adjpt Setting
<INCL> [+][ 0.00]
grams
NEXT
when done, push START