Chapter 5 General Operation
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
189
acquire the point. Alternately, the measurement may be
entered manually using ENTER MEAS MANUALLY.
2. Run the prop at its normal high power/torque rating.
Press the TAKE HI PWR/TORQUE context key and
acquire the measurement similar to the low power menu.
3. If the moveline is over 0.4 IPS the last line of the main
moveline menu will show: Moveline= 0.42 IPS-HI.
Correct the problem using manufacturer’s procedures.
4. Press START to continue. At this point the measurement
can be annotated and saved using the following screen.
5. The SAVE RUN context must be pushed to save the run.
6. Once saved the Moveline Check run can be reviewed
and printed similar to other logs using the REVIEW and
PRINT hard keys.
MOVELINE CHECK Run 1
MEAS: LOW PWR/TORQUE
BAL CHAN: <1A>
ENTER MEAS MANUALLY
if ok, push START
RUN 1 MOVELINE CHECK
23FEB13 10:50:15
[ANNOTATE]
SAVE RUN 1 of 8
don t save, push START