Chapter 2 System Overview
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
13841 Rev A
18
Characteristic
Specifications (Continued)
Date and time stamping
Yes
Log (data) files -
contents and formats
Balance jobs, log book, balance, spectrum,
fault log, all in ASCII format
Compatible software
(ground based)
Honeywell V2K Download and V2K Plot
programs
Basic Performance
Frequency range
0 to 10,000 Hz
Accuracy
±.5dB, from 5 Hz to 500 Hz; ±1dB, from
500 Hz to 10,000 Hz
Acquisition capability
2 vibration and 2 tachometer (azimuth)
Balance Measurements
Phase units
Hours and minutes
Phase resolution
2 min or 1°
Phase accuracy
±15°
Balance frequency range
120 to 30,000 RPM
Spectrum Analysis
Analysis ranges
(maximum frequencies)
1200, 3000, 6000, 12,000, 30,000, 60,000,
120,000, 300,000 and 600,000 RPM
Window type
Flat top
FFT resolution
400 lines
Signal Conversion (Vibration Inputs)

Table of Contents