104 Xenon Ultra 196X Series User Guide
SEQBLK62999943FF6A999954FF7299994DFF.
The data is output as:
CODE39SMPLTSTMSGCODE128MSGPDF417
Output Sequence Example 2 - Three Symbologies with <> Separators
In this example, you are scanning the same three barcodes, but you want <>
brackets and a carriage return and line feed to separate your output.
The sequence editor would use the same command line as shown in Output
Sequence Example 1 - Three Symbologies (page 103):
SEQBLK sequence editor start command
62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all
lengths
43 start character match for Code 39, 43h = "C"
FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all
lengths
54 start character match for Code 128, 54h = “T”
FF termination string for first code
72 code identifier for PDF417
9999 code length that must match for PDF417, 9999 = all
lengths
4D start character match for PDF417, 4Dh = “M”
SEQDFT;SEQ_EN1;SEQBLK62999943FF6A999954FF7299994DFF.