4. First scan Code 128, and then scan PDF417. Output
TSTMSGCODE128MSGPDF417
5. First scan PDF417, and then scan Code 128. Output
TSTMSGCODE128MSGPDF417
Default Output Sequence
Default Sequence programs the scanner to all universal values. Be certain you
want to delete or clear all formats before you read the Default Sequence symbol.
Require Output Sequence
When an output sequence is Required, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host device. When
it’s On/Not Required, the scanner will attempt to get the output data to conform to
an edited sequence but, if it cannot, the scanner transmits all output data to the
host device as is, or formatted according to the partial sequence output format
(see Partial Sequence on page 105).
When the output sequence is Off, the barcode data is output to the host as the
scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Good Read Tone - Output Sequences
The scanner may be programmed to either beep or click in response to a good read
of each barcode in an output sequence, or to emit a beep or error tone for a partial
sequence. Default = Good Read Click - Each Code in Sequence
and Error Tone -
Partial Sequence Output.
Default Sequence
Required
On/Not Required
*Off