Xenon Ultra 196X Series User Guide 105
FF termination string for third code
But you would add your <> separators for each sequence:
SEQSEP99 separator for each sequence, 99 = all symbologies
3C left bracket (<)
3E right bracket (>)
And add the carriage return and line feed as a suffix:
SEQSUF99 separator for suffixes, 99 = all symbologies
0D carriage return
0A line feed
The whole command line would look like this:
SEQBLK62999943FF6A999954FF7299994DFF;SEQSEP993C3E;SEQSUF990D
0A.
The data is output as:
CODE39SMPL<>TSTMSGCODE128<>MSGPDF417 [CR] [LF]
Enter Output Sequence
If you are using barcodes to create your output sequence, scan Enter Output
Sequence to begin scanning your string.
Partial Sequence
If an output sequence operation is terminated before all your output sequence
criteria are met, the barcode data acquired to that point is a “partial sequence.” You
can define how partial sequences are output using the same types of command
strings you used to create output sequences.
SEQDFT;SEQ_EN1;SEQBLK62999943FF6A999954FF7299994DFF;SEQSEP993C3E;SEQSUF990D0A.
Enter Output Sequence