106 Xenon Ultra 196X Series User Guide
Partial Sequence Example - Three Symbologies with <> Separators, but with a
Damaged Code
In this example, you are scanning PDF417, Code 128, and Code 39 barcodes, and
you want the scanner to output Code 39 first, Code 128 second, and PDF417 third,
in brackets, as shown below, but the Code 39 barcode has been damaged and
cannot be output.
You would use the same command line as shown in Output Sequence Example 2 -
Three Symbologies with <> Separators (page 104):
SEQBLK sequence editor start command
62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all
lengths
43 start character match for Code 39, 43h = "C"
FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all
lengths
54 start character match for Code 128, 54h = “T”
FF termination string for first code
72 code identifier for PDF417
9999 code length that must match for PDF417, 9999 = all
lengths
4D start character match for PDF417, 4Dh = “M”
FF termination string for third code
But you would add your <> separators for each sequence:
SEQISE99 separator for each sequence, 99 = all symbologies
3C left bracket (<)
3E right bracket (>)
And add the carriage return and line feed as a suffix: