Xenon Ultra 196X Series User Guide 107
SEQISU99 separator for suffixes, 99 = all symbologies
0D carriage return
0A line feed
And you would add >PARTIAL< as the prefix to note the partial sequence:
SEQTTS1 transmit partial sequence
SEQIPR99 add partial sequence prefix, 99 = all symbologies
3E right bracket (>)
50 P
41 A
52 R
54 T
49 I
41 A
4C L
3C left bracket (<)
The whole command line would look like this:
SEQBLK62999943FF6A999954FF7299994DFF;SEQISE993C3E;SEQISU990D0
A;SEQTTS1;SEQIPR993E5041525449414C3C.
The data is output as:
>PARTIAL<TSTMSGCODE128<>MSGPDF417 [CR] [LF]
Discard Partial Output Sequence
If you want to discard partial sequences when the output sequence operation is
terminated before completion, scan Discard Partial Sequence.
SEQDFT;SEQ_EN1;SEQBLK62999943FF6A999954FF7299994DFF;SEQISE993C3E;SEQISU990D0A;
SEQTTS1;SEQIPR993E5041525449414C3C.
* Discard Partial Sequence