Xenon Ultra 196X Series User Guide 51
Battery/Battery-Free Supercapacitor Information
Scan the barcode below to determine if you have a battery or a battery-free
supercapacitor.
Scanner Modes
Your scanner is capable of working in single scanner mode, multiple scanner
mode, or with Bluetooth devices other than the base or Access Point.
Charge Only Mode
There may be times when you want to charge your scanner, but not link to the base.
For example, if a scanner is linked to an Access Point or other Bluetooth device and
you need to charge the scanner, but want to retain your existing link.
In order to program the base for Charge Only Mode, you must link a scanner to it.
Once the scanner is linked to the base, scan the Charge Only Mode barcode. Any
subsequent scanners placed in that base will charge without linking to it. The
scanner used to program the base remains linked to the base. To unlink this
scanner, scan Unlink Scanner on page 52.
Note: When in Charge Only Mode, the scanner periodically wakes up and beeps. See Power
Up Beeper on page 77 to change this setting.
Charge and Link Mode
If you want to charge a scanner and link to the base, use Charge and Link Mode. If
the base is programmed for Charge Only Mode, you must link a scanner to it first in
order to program it for Charge and Link Mode. Scan the linking barcode on the
base to link the scanner, then scan Charge and Link Mode. Default = Charge and
Link Mode.
Battery/Battery-Free
Supercapacitor Info
Charge Only Mode
* Charge and Link Mode