72 Xenon Ultra 196X Series User Guide
Scan the Maximum Link Attempts barcode, then scan the number of attempts for
the setting (from 0-100) from theProgramming Chart, beginning on page 309,
then Save. Default = 0.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause
the scanner to try to link until the Power Time-Out Timer setting expires. When Auto
Reconnect Mode is Off, setting Maximum Link Attempts to zero will cause the
scanner to only attempt linking one time after a trigger press.
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts. An attempt to link
a scanner to a base or an Access Point typically lasts up to 5 seconds. This is the
time when the scanner is actually attempting a contact. Relink Time-Out controls
the amount of time, in seconds, that elapses between the end of one connection
attempt and the start of the next.
Note: The length of time for an attempt depends on the number of scanners connected to
a base unit or Access Point. An extra 7 seconds may be required when a connection is
successful.
Scan the Relink Time-Out barcode, then scan the number of seconds for the
setting (from 1-100) from the Programming Chart, beginning on page 309, then
Save. Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to connect
to the base unit or Access Point. Each attempt consists of approximately 5 seconds
of active time followed by 3 seconds of idle time. After one hour, the scanner
powers off and batch mode data is lost.
Example: Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, 15 attempts are made to link to the base unit
or Access Point. Each attempt consists of approximately 5 seconds of active time
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes,
Maximum Link Attempts
Relink Time-Out