Xenon Ultra 196X Series User Guide 255
Trigger Toggle Timeout Trigger Toggle Timeout (Range 0 -
65) *5
TRGTGT## 84
Serial Trigger Mode Read Time-Out
(0 - 300,000 ms) *30,000
TRGSTO#### 84
Presentation Mode Presentation Mode PAPTPR 85
Camera Motion Presentation Mode Camera Motion On TRGCAM1 85
*Off TRGCAM0 85
Object Detection Mode *Short Range AOSRNG1 85
Mid Range AOSRNG2 85
Presentation Mode Aimer Ambient Light Only PDCLED0 97
*Ambient and Scanner Light PDCLED1 97
Presentation LED Behavior After
Decode
*LEDs On TRGPCK1 86
LEDs Off TRGPCK0 86
Presentation Centering Window Presentation Centering On PDCWIN1 87
*Presentation Centering Off PDCWIN0 87
Left of Presentation Centering
Window (*40%)
PDCLFT### 88
Right of Presentation Centering
Window (*60%)
PDCRGT### 88
Top of Presentation Centering
Window (*40%)
PDCTOP### 87
Bottom of Presentation Centering
Window (*60%)
PDCBOT### 87
Presentation Reread Control Forget History & Run All the Time TRGRRCO 88
Do Not Forget History & Run All
the Time
TRGRRC1 88
Forget History & Run During Scan
Session
TRGRRC2 88
Do Not Forget History & Run
During Scan Session
TRGRRC3 88
In-Stand Sensor Mode *Sensor On TRGSSW1 89
Sensor Off TRGSSW0 89
Poor Quality Codes Poor Quality 1D Reading On DECLDI1 89
*Poor Quality 1D Reading Off DECLDI0 89
*Poor Quality PDF Reading On PDFXPR10 89
Poor Quality PDF Reading Off PDFXPR0 90
Low Resolution PDF Codes On PDFDMI1 90
*Low Resolution PDF Codes Off PDFDMI0 90
CodeGate *CodeGate Off Out-of-Stand AOSCGD0 90
CodeGate On Out-of-Stand AOSCGD1 91
Selection
Setting
* Indicates default
Serial Command
# Indicates a numeric
entry