DescriptionError
The Set Gen command is not allowed now. The format cannot be changed at this time.742Dh
A Forced Eject command is not allowed at this time. Most likely another operation is in pro-
gress.
742Eh
Debug ERROR code.742Fh
Sensors are in a state that indicate that the sensors or Callisto is not working correctly.7430h
Sensors are in a state that indicate that the sensors or Callisto is not working correctly on a
load.
7431h
Sensors are in a state that indicate that the sensors or Callisto is not working correctly on a
grab.
7432h
Sensors are in a state that indicate that the sensors or Callisto is not working correctly on an
ungrab.
7433h
Sensors are in a state that indicate that the sensors or Callisto is not working correctly on an
unload.
7434h
The RD sensor has stopped toggling, probably because the loader mechanism is blocked or
the motor is not working.
7435h
It is unsafe to load the cartridge. A runaway condition of the FRM has been detected, probably
because the tape is broken.
7436h
Unexpected LP on a grab. One (and only one) of the LP sensors has been asserted at the
beginning of the grab.
7437h
Unexpected LP at the start of a grab. One (and only one) of the LP sensors has been asserted
at the beginning of the grab. This is logged but not a failure.
7438h
The write protect sensor does not match the expected state.7439h
The Cartridge Present sensor does not match the expected state.743Ah
Rotate reel command can not be executed at this time.733Bh
Measure Kt command can not be executed at this time.733Ch
Callisto Bus test error.7440h
In transit after initialization—no cartridge present.744Fh
In transit after initialization.7450h
Ungrab after initialization.7451h
Unknown after initialization.7452h
Timed out waiting to send a command to get DSP head-cleaning information.7453h
Timed out waiting for DSP response with head-cleaning information.7454h
Timed out waiting to set up DSP for a head-cleaning command.7455h
Timed out waiting for DSP response to head-cleaning setup.7456h
Drive error codes118