DescriptionError
No scope data available from DSP7476h
DSP failed to complete the command during the initialization process.7477h
Unable to send DSP tuning parameters.7478h
DSP failed to boot properly.7479h
Time-out on sending the Clear DSP Fault log.747Ah
Time-out on completing the Clear DSP Fault log.747Bh
Unable to send DSP Head Clean command.747Ch
An abort command was requested while one is already in progress.747Dh
An abort command has timed-out while waiting for the tape to stop.747Eh
An Adjust Speed command was requested while one is already in progress.747Fh
General load failure.7480h
EP sensor did not transition on a load, probably because no cartridge was present.7481h
CD sensor did not transition on a load.7482h
CG sensor did not transition on a grab.7483h
LP sensor did not transition on a grab.7484h
Too many retries to recover on a load or unload.7485h
Cartridge not free to rotate when Cartridge Down.7486h
The RD sensor stopped toggling while EP during a load.7487h
The RD sensor stopped toggling while IT during a load.7488h
The RD sensor stopped toggling while CD during a load.7489h
The RD sensor stopped toggling while CD during a grab.748Ah
The RD sensor stopped toggling while LP during a grab.748Bh
Invoked tension ramp retry.748Ch
FRM runaway. Too much rotation was detected in the cartridge before it was threaded.748Dh
A grab was requested but the cartridge was not loaded.748Eh
Sensors indicate that the grabber unexpectedly moved into a grab position during a load
operation.
748Fh
While parking the LP, the LM voltage was increased from 0.25V to 0.5V.7490h
While parking the LP, the LM voltage was increased from 0.5V to 0.75V.7491h
While parking the LP, the LM voltage was increased from 0.75V to 1.0V.7492h