EasyManua.ls Logo

HP ProLiant BL280c - G6 Server - Page 352

HP ProLiant BL280c - G6 Server
397 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System memory 352
Table 13-29 Provider Indication Common Properties
Property name
Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
The following tables describe the SMX Memory Provider indications that are implemented for server
platforms where available:
Table 13-30
SMX_MemoryIndication: Memory Module Predictive Failure
Property name
Property implementation
CIM_Indication
PercieivedSeverity 5 (Major)
CIM_AlertIndication
Description A memory module has failed or is predicted to fail.
(MemoryModuleCaption) where
MemoryModuleCaption is the
SMX_MemoryModule.Caption for the failing memory
module
AlertingManagedElement WBEM Path of SMX_MemoryModule instance
representing the memory module
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
ProviderName SMXMemory
RecommendedActions Check the memory configuration and replace memory
as necessary.
HP_AlertIndication
Summary Memory module has failed or is predicted to fail
EventCategory
3 (Memory)
ProbableCause 1 (Other)
ProbableCauseDescription Memory Module Failed or Predicted to Fail
Table 13-31 SMX_MemoryIndication: Memory Board Error
Property name
Property implementation
CIM_Indication
PerceivedSeverity 5 (Major)
CIM_AlertIndication

Table of Contents

Other manuals for HP ProLiant BL280c - G6 Server

Related product manuals