System memory 353
Table 13-31 SMX_MemoryIndication: Memory Board Error
Property name
Property implementation
Description A memory board has an error. (MemoryBoardCaption)
where MemoryBoardCaption is the
SMX_MemoryBoard.Caption for the failing memory
board.
Table 13-32 SMX_MemoryIndication: Memory Redundancy Degraded
Property name
Property implementation
AlertingManagedElement WBEM Path of SMX_MemoryBoard instance
representing the memory board
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
ProviderName SMXMemory
RecommendedActions Check the memory configuration and replace the
memory board and memory modules as necessary.
HP_AlertIndication
Summary Memory board error
EventCategory 3 (Memory)
ProbableCause
1 (Other)
ProbableCauseDescription Memory B
CIM_Indication
PerceivedSeverity 5 (Major)
CIM_AlertIndication
Description The Advanced Memory Protection (AMP) system is
operating with degraded redundancy. The targeted
configuration has degraded or is operating with
memory modules that have failed or predicted to fail.
(TargetConfiguration/CurrentConfiguration) where
TargetConfiguration is
SMX_MemoryRedundancySet.TargetConfiguration.
AlertingManagedElement WBEM Path of SMX_MemoryRedundancySet instance
representing the Memory Redundancy.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName SMXMemory