System memory 354
Table 13-32 SMX_MemoryIndication: Memory Redundancy Degraded
RecommendedActions Check the Advanced Memory Protection configuration
and replace the memor board and memory modules as
necessary.”
HP_AlertIndication
Summary Advanced Memory Protection degraded
EventCategory 3 (Memory)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Advanced Memory Protection Degraded
CIM_Indication
CIM_AlertIndication
Description The Advanced Memory Protection (AMP) system is
operating normally in the targeted configuration. If
redundancy was previously degraded, redundancy has
been restored. (TargetConfiguration)” where
TargetConfiguration is
SMX_MemoryRedundancySet.TargetConfiguration
AlertingManagedElement WBEM Path of SMX_MemoryRedundancySet instance
representing the Memory Redundancy.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
ProviderName SMXMemory
RecommendedActions No action is recommended.
Summary Advanced Memory Protection redundancy is now fully
operational”
EventCategory 3 (Memory)
ProbableCause 1 (Other)
ProbableCauseDescription Advanced Memory Protection now Fully Operational