A failover is indicated in the Storage LUN Details screen by the yellow warning icon and the notification
message: Fibre Channel Path Failed Over to {#:#:#:#}. The #s stand for the node port; bus number
(always 0); the target id (an array port); and the LUN number on the array.
When one path fails, automatic failover reroutes data traffic to the secondary path so the data transfer
still happens, but potentially at a slower rate. It is advised that you restore the path as soon as possible
to avoid a double path failure.
To restore the failed path:
1. Determine the cause of the failure and repair it if needed.
2. In Command View VLS, access the System tab.
3. Select Storage LUNs from the navigation tree.
4. Select View to display the storage LUN details.
5. Select Fix Primary Paths from the task bar to display the Fix Primary Paths Wizard.
6. Select Apply to set all paths back to their primary paths.
Failure of both paths (double path failure) is indicated by the red critical icon and a specific notification
message. The notification message differs based on whether the failure occurs while running or upon
booting the system.
A double path failure that occurs while running results in the critical alert Fibre Channel Paths
Failed for Lun, ulid <numerical LUN id number> wwnn <numerical wwnn>.
A double path failure that occurs upon booting the system results in the critical alert Missing Storage
LUN paths on node #.
This means the node can not communicate with the LUN at all. If the failed paths are on the primary
node, the whole storage pool containing that LUN is off-line; if the failed paths are on a secondary
node, the storage pool is on-line until reboot, but the storage pool is inaccessible from that node. In
this case, you can still get to the LUNs, but only from a different node.
To repair double path failure (assuming there has been no reboot during the failure):
1. Determine the cause of the failures and repair them if needed.
2. In Command View VLS, access the System tab.
3. Select Storage LUNs from the navigation tree.
4. Select Fix Primary Paths from the task bar to display the Fix Primary Paths Wizard.
5. Select Apply to set all paths back to their original settings.
Private LAN Dual Pathing
The private LAN on the VLS9000 has dual pathing which consists of a cable from each switch to each
node. If a LAN switch or a path to a LAN switch fails, the data transfer will automatically fail-over to
the other available switch.
The primary path is through NIC 2 of the switch and is referred to in the error notification as eth1.
If the LAN switch associated with NIC2 fails, the Notifications tab will display all eth1 failures.
The secondary path is through the USB LAN cable and is identified as eth2 in the error notification.
If the LAN switch associated with the USB LAN cable fails, the Notifications tab will display all
eth2 failures.
If both paths fail, the critical alert will identify bond 0 as the combined failed path. If both paths
from the private LAN to a secondary node fails, the node is off-line; but if both paths to a primary
node fails, the whole device is off-line.