2. Erase all the virtual media from the disk array enclosures and rebuild all the RAID volumes on
the storage pool affected:
a. Select Storage Pools in the navigation tree, then select the storage pool that needs recovery.
b. Click Rebuild Storage Pool in the task bar.
c. Click Rebuild.
d. Click Yes to confirm.
3. Recreate the cartridges that existed on the VLS storage pool.
VLS cartridge configurations are stored on the disk arrays and have been erased.
Recovering from a Node RAID Volume Failure
To recover from a node RAID volume failure, which occurs when both node hard drives fail:
1. When restoring a primary node, power down all of the secondary nodes.
2. Replace the failed node hard drives.
3. Install the operating system on the new hard drives and restore the VLS. See Recovering from
Operating System Failure.