Fibre Channel Switch 4/16q #1
DescriptionItem
FC cable from port 3 of 7th node (if present), or FC port 0 of RAID controller 0 of 10th array
(if present)
8
FC cable from port 3 of 8th node (if present), or FC port 0 of RAID controller 0 of 9th array
(if present)
9
FC cable from FC port 0 of RAID controller 0, 2nd 8th arrays (if present)1016
FC cable from FC port 0 of RAID controller 0 of 1st array (array 0)17
Empty, or XPAK transponders from the interswitch link kit (if present)1821
Fibre Channel Switch 4/16q #2
DescriptionItem
Ethernet cable from port 23 of Ethernet Switch 281024G1
FC cable from FC port 4 of primary node2
FC cable from FC port 4 of 2nd 6th nodes (if present)37
FC cable from FC port 2 of 7th node (if present), or FC port 0, of RAID controller 1 of 10th
array (if present)
8
FC cable from FC port 2 of 8th node (if present), or FC port 0, of RAID controller 1 of 9th
array (if present)
9
FC cable from FC port 0 of RAID controller 1, 2nd 8th arrays (if present)1016
FC cable from FC port 0 of RAID controller 1 of 1st array (array 0)17
Empty, or XPAK transponders from the interswitch link kit (if present)1821
Locate 2 meter Fibre Channel cables from the array kit contents.
1. Connect one end of a Fibre Channel cable to port 15 of Fibre Channel Switch 4/16q #1. Connect
the other end of the Fibre Channel cable to Fibre Channel port 0 of RAID controller 0 of the first
array (array 0).
2. Connect one end of a Fibre Channel cable to port 15 of Fibre Channel Switch 4/16q #2. Connect
the other end of the Fibre Channel cable to Fibre Channel port 0 of RAID controller 1 of the first
array (array 0).
3. With multiple arrays:
a. Working backwards from the last Fibre Channel port on Fibre Channel switch #1, connect
one end of a Fibre Channel cable to the next available Fibre Channel port on Fibre Channel
switch #1. Connect the other end of the Fibre Channel cable to Fibre Channel port 0 of
RAID controller 0 of second array (array 1).
b. Working backwards from the last Fibre Channel port on Fibre Channel switch #2, connect
one end of a Fibre Channel cable to the next available Fibre Channel port on Fibre Channel
switch #2. Connect the other end of the Fibre Channel cable to Fibre Channel port 0 of
RAID controller 1 of second array (array 1).