EasyManua.ls Logo

HSD ES919 NC - Cleaning the Tool Holder Cone; Protecting the Spindle Shafts Conical Housing

Default Icon
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
______HSD Technological equipment for Automation _____________________________________
5801H0017 Rev. 02 _________________________________________________________ 69/98
DIRTY MATING SURFACES CAUSE AN UNCORRECT TOOL HOLDER
SEATING, WITH SERIOUS CONSEQUENCES FOR OPERATOR
SAFETY, ELECTRO-SPINDLE AND TOOL HOLDER WEAR, AND
MACHINING PRECISION.
USE A CLEAN AND SOFT CLOTH TO CLEAN THE CONICAL
SURFACES AND THE FACES SHOWN IN FIGURES FROM Figure 12.1
TO Figure 12.4. ABSOLUTELY NEVER USE ABRASIVE TOOLS OR
MATERIALS LIKE METAL BRUSHES, EMERY CLOTH, ACIDS AND
OTHER AGGRESSIVE CHEMICALS.
12.1.2 Cleaning the tool holder cone
EVERY TWO WEEKS
Clean carefully the conical surface of the tool holder (shown in black in Figure 12.1 and Figure
12.2) using a clean, soft cloth dipped in ethyl alcohol.
HSK VERSION ONLY: after cleaning by ethyl alcohol, spray the product KLÜBER LUSIN
PROTECT G 31, on the conical surface, and spread the product evenly using a clean, dry cloth.
12.1.3 Protecting the spindle shaft's conical housing
DAILY
DIRT MUST NOT BE ALLOWED TO ENTER THE CONE SEAT. CLOSE IT
WITH A SUITABLE PLUG OR A SPARE TOOL HOLDER.
AT THE END OF THE WORKING DAY, ALWAYS REMOVE THE TOOL
HOLDER FROM THE SPINDLE, TO PREVENT IT FROM STICKING.
PROTECT OR COVER THE SPINDLE NOSE AGAINST
CONTAMINATION.