______HSD Technological equipment for Automation _____________________________________
5801H0017 Rev. 02 _________________________________________________________ 83/98
6
Remove only the six screws shown to
release the cylinder.
7
Fit the new cylinder using the six screws
removed in step 6.
C
Quick-fit union with pressure
regulator
D
Compressed air line internal
pressurization
E
Compressed air inlet for cone
cleaning and pressurization
H
Connection hose
M
Pressure gauge
8
C
Quick-fit union with pressure
regulator
N
Adjuster
P
Lock nut
9
Fit a pressure gauge M as shown in step
8 to measure the outlet pressure from
union C.
Connect an air supply at 4 bar (58 PSI) to
E.
Turn adjuster N until the pressure on the
gauge reads 0.8 bar (11.6 PSI).
Tighten lock nut P to lock the adjustment.
Disconnect the pressure gauge M and
hoses D and H from union C.
N
P
C
D
C
E
M
H