Figure 5-4 Querying the health status for the RH2288H V3
d. Clear alarms. For details, see
Huawei Rack Server iBMC Alarm
Handling
.
If the query result in c indicates that no alarm is generated for the server, skip
this step.
● Check the RH2288H V3 using the iBMC CLI.
a. Log in to the iBMC CLI.
i. Set an IP address for the PC, and ensure that the IP address is on the
same network segment as the iBMC management network port.
ii. Connect the PC to the RH2288H V3 iBMC management network port
by using a network cable.
iii. Run a command line management tool (such as SSH and PuTTY)
tool on the PC, and enter the IP address of the iBMC management
network port, user name, and password to log in.
By default, SSH is used to log in to iBMC. If the SSH service is disabled,
enable it by choosing
Cong > Service Settings on the iBMC WebUI.
b. View the RH2288H V3 version information.
Check that the RH2288H V3 versions meet site requirements.
Hi1710 / # ipmcget -d v
------------------- iBMC INFO -------------------
IPMC CPU: Hi1710
IPMI Version: 2.0
CPLD Version: (U46)1.05
Active iBMC Version: (U25)1.26
Active iBMC Built: 08:26:05 Dec 23 2014
Backup iBMC Version: 1.26
SDK Version: 1.47
SDK Built: 08:28:02 Dec 19 2014
Active Uboot Version: 1.1.29 (Oct 13 2014 - 15:23:00)
Backup Uboot Version: 1.1.29 (Oct 13 2014 - 15:23:00)
----------------- Product INFO -----------------
Product ID: 0x0001
Product Name: RH2288H
Product Version: V3
BIOS Version: (U47)1.19
-------------- Mother Board INFO ---------------
RH2288H V3 Server
User Guide 5 Conguring the RH2288H V3
Issue 46 (2022-12-28) Copyright © Huawei Technologies Co., Ltd. 126