Procedure
Step 1 Log in to the iBMC WebUI over a network port. For details, see 9.2 Logging In to
the iBMC WebUI.
Step 2 Choose Cong > Security Enhance.
Step 3 Select Enable for Password Complexity Check.
The system will perform a password complexity check when a new password is
set.
Step 4 Choose
Cong > Local User, as shown in Figure 5-16.
Figure 5-16 Local User page
Step 5 Click next to the user whose password needs to be changed.
Step 6 Change the password as prompted.
● When the password complexity check function is disabled, the password can
be empty or a string of any characters fewer than 20 characters.
● When the password complexity check function is enabled, the password must
meet the following requirements:
– Must contain 8 to 20 characters.
– Must contain at least one space or one of the following special
characters:
`~!@#$%^&*()-_=+\|[{}];:'",<.>/?
– Must contain at least two types of the following characters:
▪ Uppercase letters
▪ Lowercase letters
RH2288H V3 Server
User Guide 5 Conguring the RH2288H V3
Issue 46 (2022-12-28) Copyright © Huawei Technologies Co., Ltd. 137