Turning an Input/Output On or Off 93
User Guide v 1.4 — September 2015 System Options
11.4.2 Turning an Input/Output On or Off
Neo2 allows the operator to set each Input or Output to On or Off. Inputs/outputs that are On
are enabled to and inputs/outputs that are Off are disabled.
To turn a input or output on or off:
1. On the OPTIONS screen touch Inputs or Outputs.
2. On the Input or Output screen, touch the input or output you want to adjust.
3. Using the scroll buttons, scroll to the option.
4. Touch ON/OFF to toggle the selected zones from ON to OFF or vice versa.
5. Touch OK.
11.4.3 Configuring Input or Output Channels as Normally Open or Closed
Digital inputs are activated by relay switches, located in a separate piece of equipment, that
are wired to the I/O box. The Inputs or Outputs screen allows all digital input or output
channels to be configured as normally open or normally closed.
To configure each the input or output channel to normally Open or Closed:
Figure 11-3 Inputs Screen
1. Input Number 2. Selected Input 3. Current Option Value 4. Option Type 5. Option Scroll
Buttons 6. Select All Button 7. Clear All Button 8. Block Button